MPO/APC-FC/UPC SM 8F G652D 3.0mm LSZH
March 4, 2025

L≤1m |
-1cm≤△L≤+5cm |
1m<L≤10m |
-10cm≤△L≤+10cm |
L≥10m |
-10cm≤△L≤1%*L |

Connector1 |
Connector2 |
Endface Type |
Fiber Type |
Cable Diameter |
Sheath Material |
Colour |
MPO |
FC |
APC/UPC |
G652D |
3.0mm |
LSZH |
Yellow |
It can also be customized according to the specifications specified by customers. |

Cable Diameter (mm) |
Inner Sheath Diameter(mm) |
Tension(N) Long term/ Short term |
Crush Resistance(N/100mm) Long term/Short term |
|
|
|
|
3.0±0.2 |
0.25±0.05 |
30/100 |
100/300 |
Item |
Connector |
Insertion Loss(dB) |
MPO≤0.75,FC≤0.3 |
Return Loss(dB) |
SM:≥50(UPC) ≥60(APC); MM:≥25(PC) |
Conform to criterion |
IEC61754 |
(1) Vibration test
Test criterion:IEC 61300-2-1
Amplitude:0.75mm
Frequency sweep range:10~50HZ/minute
Time:30minutes
After test:
a)No mechanical damage, such as deformation, crack, slack, etc
b) The optical performance conforms to Table 5
(2) Impact test
Test criterion:IEC 61300-2-12
Drop height:1.5m
Drop times:5/times
After test:
a)No mechanical damage, such as deformation, crack, slack, etc
b) The optical performance conforms to Table 5
(3)Mating durability test
Test criterion:IEC 61300-2-2
Durability:500/times
After test:
(3) Change of temperature:
b) The optical performance conforms to Table 5
No mechanical damage, such as deformation, crack, slack, etca)No mechanical damage, such as deformation, crack, slack, etc
b) The optical performance conforms to Table 5
(2) Low temperature test
Test criterion:IEC61300-2-17
Test criterion:-25℃
Time:96/hours
After test:
(1) High temperature test
Test criterion:IEC61300-2-18
Temperature:70℃
Time:96 /hours
After test:
a)No mechanical damage, such as deformation, crack, slack, etc
b) The optical performance conforms to Table 5
Environmental performances
Test criterion:IEC 61300-2-22
Temperature range:-25℃to + 70℃
Time:96/hours,12/cycles
After test:
b) The optical performance conforms to Table 5
No mechanical damage, such as deformation, crack, slack, etcb) The optical performance conforms to Table 5
(4) Damp heat
Test criterion:IEC 61300-2-19
Test condition:40℃,93% RH
Time:96/hours
After test:
No mechanical damage, such as deformation, crack, slack, etc 光学性能符合表五
No. |
Test Item |
Insertion Loss variation(dB) |
1 |
Vibration test |
≤0.2 |
2 |
Impact test |
≤0.2 |
3 |
Mating durability test |
≤0.2 |
4 |
High temperature test |
≤0.2 |
5 |
Low temperature test |
≤0.2 |
6 |
Change of temperature |
≤0.2 |
7 |
Damp heat |
≤0.2 |
Opration temperature: -25℃~+70℃
Installation temperature: -10℃~+60℃
Storage temperature: -40℃~+85℃