Cable Construction

Cross Sectional Diagram

ADSS
Technical Specification

Fiber Counts

2~48F

 

Loose Tube

Material

PBT

 

OD(mm):

2.0± 0.1 mm

 

Fiber per tube

12F

Water Blocking Material

Water Blocking Tape

Central Strength member

2.1mm FRP

supporting Member

Aramid yarnsr

 

Sheath

Material:

HDPE

 

Color:

Black

Cable

Diameter

10.0 ± 0.5 mm

 

Weight

75±5 kg/km

Rate Tensile strength (RTS)

3.5KN

Maximum allowable tension (MAT 40% RTS)

1.4kN

Maximum installation tension (≤20% RTS)

0.7KN

Strain Margin Strength (60%RTS)

2.1KN

Everyday Stress (16%~25%RTS)

0.6~0.9KN

Max. span

100M

Crush resistance

1000N/100mm

Operating temperature

-40℃~+60℃

Store/Transport temperature

-40℃~+70℃

Installation temperature

-30℃~+50℃

 
Fiber and Loose buffer tube Identification

NO.

1

2

3

4

5

6

7

8

9

10

11

12

Fiber

Color

 

Blue

 

Orange

 

Green

 

Brown

 

Grey

 

White

 

Red

 

Black

 

Yellow

 

Violet

 

Pink

 

Aqua

Optical Fiber

ITEMS

UNITS

SPECIFICATION

Fiber Type

-

G652D

 

Attenuation

 

dB/km

Before Cable

After Cable

 

 

1310 nm≤ 0.34

1550 nm≤ 0.21

1310 nm≤ 0.35

1550 nm≤ 0.24

 

Chromatic Dispersion

 

ps/nm.km

1310 nm≤ 3.5

1550 nm≤ 18

1625 nm≤ 22

Zero Dispersion Slope

ps/nm2.km

0.093

Zero Dispersion Wavelength

nm

1300 ~ 1324

PMD (M=20, Q=0.01%)

ps/√km

≤ 0.2

Cut-off Wavelength (lcc)

nm

≤ 1260

Attenuation vs. Bending

(60mm x100turns)

dB

≤ 0.1 at 1625 nm

(60mm x100turns)

Mode Field Diameter

mm

(8.6-9.5) ± 0.7 @1310nm

Core-Clad Concentricity

mm

≤ 0.5

Cladding Diameter

mm

125±2

Cladding Non-circularity

%

≤ 0.8

Coating Diameter

mm

245±5

Proof Test

Gpa

≥ 0.69

 
 
Mechanical and Environmental Performance of the Cable

N O

.

ITEMS

TEST METHOD

ACCEPTANCE CRITERIA

 

 

1

Tensile Loading Test

IEC 60794-1-E1

-. Tensile load:1200N

-. Maintained time:1min

- Length of cable: about 150m

-.Attenuation increment@1550nm:≤0.1dB

-. No jacket cracking and fiber

breakage

 

 

2

Crush Resistance Test

IEC 60794-1-E3

-.Load:1000 N/100mm

-Load time:≥1 minutes

-.Attenuation increment@1550nm:≤0.1dB

-. No jacket cracking and fiber

breakage

 

 

 

3

 

Impact Resistance Test IEC 60794-1-E4

Points of impact:3 Times of per point: 2 Impact energy: 4.5J

Radius of hammer head: 12.5mm

Impact rate: 2sec/cycle

 

-.Attenuation increment@1550nm:≤0.1dB

-. No jacket cracking and fiber breakage

 

 

 

 

4

 

Repeated Bending

IEC 60794-1-E6

 

Bending Dia.: 20 x OD Load: 150N

Flexing rate: 3sec/cycle No. of cycle: 30

 

-.Attenuation increment@1550nm:≤0.1dB

-. No jacket cracking and fiber breakage

 

 

 

5

 

 

Torsion Test IEC 60794-1-E7

Length: 1m Load: 150N

Twist rate: 1min/cycle

Twist angle: ±180° No. of cycle: 10

 

-.Attenuation increment@1550nm:≤0.1dB

-. No jacket cracking and fiber breakage

 

 

6

Water Penetration Test

#Test method:IEC 60794-1-F5B

-.Height of pressure head:1m

-.Length of specimen:3m

-.Test time: 24 hours

 

-. No leakage through the open cable end

 

 

 

7

 

 

Temperature Cycling Test IEC 60794-1-F1

-.Temperature steps:+20℃、-

40℃、+60℃、+20℃

-.Testing Time:12 hours/step

-.Cycle index:2

 

-. Attenuation increment@1550nm:≤0.1dB

-. No jacket cracking and fiber

 

 

 

breakage

8

Compound Flow

- Sample length: 30 cm

- No compound flow

 

IEC 60794-1-E14

- Temp: 70°C 2°C

 

 

 

- Time: 24 hours

 

 
Fiber Optical Cable bending radius
Static bending: ≥ 10 times than cable out diameter Dynamic bending: ≥ 20 times than cable out diameter.
Package and Mark
PACKAGE
Material of the drum shall be fumigation wood. 4km/Drum: 1100*1100*750mm;
The disc length can be customized according to customer requirements
Not allowed two length units of cable in one drum, Two ends should be packed inside drum, reserve length of cable not less than 1meter.

MARK
White color Ink jet printing, Cable Mark: Brand, Cable type, Fiber type and counts, Year of manufacture and Length marking.